Allied Edison LDL1100 Verifier Close Front Connections

Allied Edison LDL-1100 Live Dead Live Verifier

$199.95Price

10% off w/ 20 or more units

The Live Dead Live (LDL) Meter Verifier is a small, lightweight, robust, portable, handheld power supply. The LDL 1100 Meter Verifier is specifically designed to facilitate voltage verification tests on most digital multi-meters, electronic voltage detectors, voltage testers, neon test lights, tic tracers and other commonly used electrical voltage test apparatus, while keeping the user as electrically safe as possible with its extremely low “volt-amp” output. It supplies just under 50 volts, AC (rms) or DC with a maximum current of less than 5 mA at rated voltage for testing.

Quantity
  • Specifications

    INPUT: 9 volt battery. OUTPUT VOLTAGE: 49 volts (rms). OUTPUT CURRENT: Under 5 mA. 7.5 lb. pull force magnet Switch auto shutoff and under voltage shutdown

  • Related Regulations

    OSHA 1910.333(a)(1)

     

          OSHA has not accepted the argument that a qualified employee can work on energized circuits as safely as they can work on de-energized circuits. Therefore, OSHA is not leaving it to the employer’s discretion as to whether or not to de-energize electric circuits on the basis of convenience, custom, or expediency.       OSHA requires that all live parts to which an employee may be exposed shall be de-energized before the employee works on or near them, unless the employer can demonstrate that de-energizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations.

     

    NFPA – National Fire Protection Association (Article 120)

     

    120.1 Process of Achieving an Electrically Safe Work Condition. An electrically safe work condition shall be achieved when performed in accordance with the procedures of 120.2 and verified by the following process:

    • Determine all possible sources of electrical supply to the specific equipment. Check applicable up-to-date drawings, diagrams, and identification tags.

    • After properly interrupting the load current, open the disconnecting device(s) for each source.

    • Wherever possible, visually verify that all blades of the disconnecting devices are fully open or that drawout-type circuit breakers are withdrawn to the fully disconnected position.

    • Apply lockout/tagout devices in accordance with a documented and established policy.

    • Use an adequately rated voltage detector to test each phase conductor or circuit part to verify they are de-energized. Test each phase conductor or circuit part both phase-to-phase and phase-to-ground. Before and after each test, determine that the voltage detector is operating satisfactorily.

     

    NIOSH – National Institute of Occupational Safety & Health

     

          Before any work is done on a circuit, shut off the circuit, lock out and tag out the circuit at the distribution panel, then test the circuit to make sure it is de-energized. Before ANY equipment inspections or repairs – even so-called low-voltage circuits – the current must be turned off at the switch box, and the switch must be padlocked in the OFF position. At the same time, the equipment must be securely tagged to warn everyone that work is being performed. Again, test circuits and equipment to ensure they are de-energized.

     

    INPO – Institute of Nuclear Power Operations

     

          Expectations have been established for voltage-detection work practices, such as “test-before-touch” and “live-dead-live” verifications. Workers are expected to understand the limitations of voltage-detectors, such as proximity testers. Thorough voltage-detection is expected. Voltage checks should include exposed electrical conductors or circuit parts in poximity to the circuit to be worked.

  • Statistics

    Electrical hazards cause more than 300 deaths and 4,000 injuries in the workplace each year. Electrical accidents rank sixth among all causes of work-related deaths in the United States. During the work day, a worker is hurt every 30 minutes so severely from electricity that it requires time off the job. Reference: Electrical Safety Foundation International (ESFI) – Electrical Safety in the Workplace Fact Sheet  

  • Practical Examples

    Example #1

     

          A worker has to climb a high ladder or is on scaffolding 4 stories high in order to work on a circuit. What does the worker do to ensure the circuit is de-energized? In order to perform a “live-dead-live” test and check his meter, he would have to climb all the way down and try to find a live voltage source both before AND after testing the circuit he wants to work on. Make it easy to be safe by using a portable Live-Dead-Live verifier.

     

    Example #2

     

          When working on a DC system, a worker cannot find a DC voltage source with which to check his meter to properly perform the “live-dead-live” test. What does the worker do to ensure the circuit is de-energized? I’d like to say the worker searches until he finds an appropriate DC source with which to test his meter, in reality, many times this vital test is not conducted. This is a perfect example of how needless accidents occur because of failing to perform a proper test. Make it easy to be safe by using a portable Live-Dead-Live verifier.

    Example #3

     

          A worker with an LDL verifer needs to verify that he has properly de-energized the circuit he is working on. What does the worker do to ensure the circuit is de-energized?

    • He turns on his LDL verifier.

    • He tests his meter with the LDL verifier to ensure that is working properly.

    • He tests the circuit he is about to work on to see that it is dead.

    • He then retests his meter with the LDL verifier to show that it is working.

    This entire operation took about one minute and now that worker can safely work on the de-energized circuit. Make it easy to be safe by using a portable Live-Dead-Live verifier.

Introducing the ZX3 DC Ground Detection and Location Equipment

Introducing the Allied Edison ZX3 DC Ground Detection and Location Equipment

Introducing the Allied Edison ZX3 DC Ground Detection and Location Equipment

Please watch the video above for introductory information about the ZX3 DC Ground Detection and Location Equipment by Allied Edison.

Three Location Modes Built Into One Machine

ZX3 DC Ground Detection Tracer & Base Fast Locate Mode

Fast Locate Mode

A Fast Locate mode that can find faults in a typical 135 vdc low capacitive (≤ 2 μF) system that are from 0 Ω to >100 kΩ very quickly and accurately.

ZX3 DC Ground Detection Tracer & Base Fast Precise Locate Mode

Precise Locate Mode

A Precise Locate mode that can find faults in a typical 135 vdc low to high capacitive (≤ 50 μF) system that are from 0 Ω to >100 kΩ quickly and with extreme precision.

ZX3 DC Ground Detection Tracer & Base Intermittent Locate Mode

Intermittent Locate Mode

An Intermittent Locate mode, which can find an intermittent or cycling fault in a 135 vdc system where system capacitance is zero and the fault is ≤ 8 kΩ or where system capacitance is 2 μF and the fault is ≤ 25 kΩ.

ZX3 -- Z for impedance, X for times, 3 for location methods

​

The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.

​

Three Location modes built into one DC ground location machine, which allows ZX3 to find ground faults under any condition:

  • Fast Locate mode that can be used to find grounds in low capacitive environments. In these conditions, grounds can be located very quickly and accurately.

  • Precise Locate mode can find DC ground faults in a typical 135 Vdc low to high capacitive (≤50 μF) systems that are from 0 Ω to >100 kΩ quickly and with extreme precision and works on system voltages from 24 vdc to 600 Vdc (including solar applications).

  • Intermittent Ground Locate mode, which can find an intermittent or cycling DC ground faults in battery systems or Solar Strings.

  • The ZX3 is the only machine available on the market that offers a way to locate an Intermittent Ground Fault.  

​

Two additional operational modes:

  • Ground fault "Detect/Analyze" mode where resistances values electrical parameters are calculated and displayed.

  • Self Test mode, determines any abnormalities in operating the equipment

​

Works on ungrounded or floating DC systems from 24 to 600 volts, including Solar Generation.

ZX3 DC Ground Detector USB Data Logging

The ZX3 supports Data Logging onto a flash drive for remote viewing of the DC ground for an extended period of time.

ZX3 DC Ground Detector Base & Tracer Magnetic straps

The ZX3 has a protective rubber boot around the Base and Tracer Units to make them more rugged and durable, and a magnetic strap so that the system can be hung at eye level.

ZX3 DC Base & Tracer with Backstand

The Base and Tracer Units also have “fold out” stands that allow them to be placed on a bench top.

ZX3 DC Ground Tracer Unit illuminated LED

The ZX3 illuminates very brightly in dark areas, making ground location as easy at night as in the day.

Hazards of Ground Faults on a DC Ungrounded System

Hazards of Ground Faults on a DC Ungrounded System (Allied Edison Explainer)

Hazards of Ground Faults on a DC Ungrounded System (Allied Edison Explainer)

Please watch the video above for further saftey information about the ZX3 DC Ground Detection and Location Equipment by Allied Edison.

ZX3 Ground Detection through metal conduit
ZX3 Ground Detection through conduit, raceway, and pipes

The ZX3 Tracer has circuitry that will allow the sensor to detect ground current through a metal conduit, flexible conduit or other cable raceway without the need to have the actual wiring exposed.

The ZX3 combines analog with digital technology, yielding the most innovative, advanced, ground detection and location machine in the world!

​

The Allied Edison ZX3 is a highly advanced tool by which a DC ground fault can be analyzed for station risk objectives and located without the need to de-energize live vital circuits critical to the station or system. The ZX3 has been rigorously tested by independent laboratories for emissions, immunity, safety and health compliance and complies with all standards set forth by CE regulations. The ZX3 assists in NERC PRC-002-6 compliance, whereby the Station Battery and DC power System must be inspected for inadvertent grounds every four months and aids to overall Nuclear Safety Risk reduction.